JKSSB Ophthalmic Technician Previous Year MCQs- Optics in Optometry MCQs

Master Optics in Optometry with JKSSB Previous Year MCQs

Optics in Optometry is a cornerstone subject for candidates appearing for technical eye care examinations conducted by the Jammu & Kashmir Services Selection Board. To secure a top rank and qualify for a paramedical position, practicing authentic JKSSB Ophthalmic Technician Previous Year MCQs is absolutely essential. This specific question bank focuses on the physical, geometrical, and physiological aspects of light and lenses, providing candidates with a clear understanding of the exam’s difficulty level and recurring optical themes.

When preparing for the rigorous written objective test, relying on subject-wise JKSSB Ophthalmic Technician PYQs gives you a significant competitive edge. Questions in this section test your conceptual clarity on how light behaves both in the atmosphere and within the human eye. By actively solving these targeted JKSSB Optometry PYQs, candidates can improve their clinical reasoning, reduce the chances of negative marking, and confidently tackle complex, physics-based optometry questions.

High-Yield Optical Concepts for JKSSB Examinations

In state-level paramedical exams, the optics section frequently evaluates a candidate’s understanding of lens dynamics, light wave properties, and clinical optical phenomena. By reviewing this curated list of previous year questions, you will master several high-frequency exam topics, including:

  • Clinical Visual Axes & Angles: Understanding the angular separation between the visual and pupillary axes (Angle Kappa) and how a positive angle kappa can clinically mimic exotropia (pseudoexotropia).
  • Optical Aberrations & Distortions: Differentiating between the color fringes of chromatic aberration (caused by light dispersion) and the spatial warping of barrel distortion typically seen in high-power concave lenses.
  • Physical & Geometrical Optics: Grasping the fundamental laws of light behavior, including Malus’s law for transmission through polarizers, and Brewster’s angle for complete plane-polarization upon reflection.
  • The Electromagnetic Spectrum: Identifying the exact nanometer ranges for visible light (400 nm to 700 nm) and ultraviolet radiation (400 nm down to 1 nm).
  • Reflective Ocular Imagery: Understanding the properties of the four Purkinje images, specifically why the fourth image (P4) is the only inverted, real image formed by reflection from the posterior lens surface.
  • Light Filtration & Wave Properties: Knowing how neutral grey filters uniformly attenuate all visible wavelengths, and identifying nodes as the points of zero amplitude in a standing wave.

Practice BFUHS Previous Year MCQs on “Pediatric Optometry”:

Q-1: Which of the following statements about the fourth Purkinje image (P4) is correct? (JKSSB Ophthalmic Technician Previous Year MCQs)

A) It is a virtual image formed by reflection from the anterior lens surface
B) It is used to measure the corneal thickness
C) It is the brightest of all four Purkinje images
D) It is an inverted image formed by reflection from the posterior lens surface

Click “Show more” to see the answer and explanation.

Struggling with your optometry government job preparation? Let Samir Sir, the founder of Smart Optometry, guide you to success. Enroll in our “Gov Job Preparation” course, and we’ll provide the roadmap. Your dream job at BFUHS Ophthalmic Officer, GSSSB, AIIMS, RRB, or DHS is within reach!

Enroll Now!

Q-2: Which filter has an even transmission through the whole visible spectrum? (JKSSB Ophthalmic Technician PYQs)


A) Yellow absorbing Filter
B) Contrast Enhancing Filter
C) Blue Light Filter
D) Neutral Grey Filter

Click “Show more” to see the answer and explanation.

.



.

Q-3: What is the range of visible light in the electromagnetic spectrum? (JKSSB Ophthalmic Technician Previous Year MCQs)


A) 100 nm to 300 nm
B) 1000 nm to 1300 nm
C) 400 nm to 700 nm
D) 750 nm to 1000 nm

Click “Show more” to see the answer and explanation.

Unlock your potential with our “Gov Job Preparation” course. Gain access to a massive library of 5000+ subject-wise MCQs, 1000+ previous year questions, detailed notes, and video lectures. Everything you need for exams like BFUHS Ophthalmic Officer, AIIMS, GSSSB, PSC, and DMER is in one place.

Start Learning Today!

Q-4: What is the angle formed between the line perpendicular to the center of the cornea and the visual axis? (JKSSB Ophthalmic Technician PYQs)


A) Angle alpha
B) Angle kappa
C) Angle gamma
D) Visual angle

Click “Show more” to see the answer and explanation.

.



.

Q-5: Which is an example of dispersion of sunlight by water droplets in the atmosphere? (JKSSB Ophthalmic Technician Previous Year MCQs)


A) Mirage
B) Rainbow
C) Lightening
D) Polarization

Click “Show more” to see the answer and explanation.

Prepare for a full year of opportunities! Our “Gov Job Preparation” course gives you 12 months of access to top-quality materials and support. Cover all major exams like BFUHS Ophthalmic Officer, GSSSB, AIIMS, RRB, Ophthalmic Officer without buying multiple courses. It’s the smartest investment for your career.

Join the Course!

Q-6: What type of distortion arises due to high power concave lenses? (JKSSB Ophthalmic Technician PYQs)


A) Barrel
B) Marginal
C) Coma
D) Pincushion

Click “Show more” to see the answer and explanation.

.



.

Q-7: Which aberration arises due to shorter and longer wavelength light rays? (JKSSB Ophthalmic Technician Previous Year MCQs)


A) Spherical aberration
B) Chromatic aberration
C) Oblique astigmatism
D) Distortion

Click “Show more” to see the answer and explanation.

Don’t study alone! Our “Gov Job Preparation” course includes group updates and live support to clear all your doubts. With guidance from Samir Sir and a community of fellow aspirants, you’ll stay motivated and on track.

Get Started Now!

Q-8: In which condition positive angle kappa is seen? (JKSSB Ophthalmic Technician PYQs)


A) Pseudoexotropia
B) Pseudohypertropia
C) Incyclophoria
D) Pseudoesotropia

Click “Show more” to see the answer and explanation.

.



.

Q-9: What is the range of Ultraviolet rays in the electromagnetic spectrum? (JKSSB Ophthalmic Technician Previous Year MCQs)


A) 1mm to 700 nm
B) <10-3 nm
C) 1nm to 10-3 nm
D) 400 nm to 1nm

Click “Show more” to see the answer and explanation.

Ready to secure your government job in optometry? The “Gov Job Preparation” course is your final destination. With a proven success strategy, expert mentorship, and over 6000 MCQs, we make your preparation seamless and effective. Click the link to begin your journey!

Enroll for Success!

.

Q-10: In a sinusoidal wave, what is the name of the points where the amplitude is zero? (JKSSB Ophthalmic Technician PYQs)


A) Antinode
B) Resonance
C) Node
D) Mode

Click “Show more” to see the answer and explanation.

.


Locked Premium MCQs – Instrumentation

🔒 Bonus MCQs – Available in App

Unlock these 10 exclusive premium questions + detailed explanations in the Govt Job Preparation course.

Question 11 (Locked)

Q-11: Which of these help in visualization of corneal cells?

A Confocal microscope

B Optical coherence tomography

C Pachymeter

D Slit lamp biomicroscope

Answer: A) Confocal microscope

A confocal microscope allows detailed, in vivo imaging of corneal cells, including endothelial and epithelial layers. It provides high-resolution cellular-level imaging essential for diagnosing corneal pathologies.

Question 12 (Locked)

Q-12: Which are not the uses of single or double frequency Nd:YAG laser?

A Spectacle removal

B Laser iridotomy

C Pan retinal photocoagulation in diabetic retinopathy

D Ablation of posterior capsular opacification

Answer: A) Spectacle removal

Nd:YAG lasers are used for iridotomy, posterior capsular opacification ablation, and sometimes diabetic retinopathy treatment. They cannot be used for spectacle removal, which requires refractive surgery like LASIK.

Question 13 (Locked)

Q-13: Slit lamp biomicroscope cannot be used for which of the following:

A Measurement of corneal epithelial defect

B Observing the optic disc and macula with 90D lens

C Laser iridectomy in angle closure glaucoma

D Fluorescein staining with cobalt blue light

Answer: C) Laser iridectomy in angle closure glaucoma

A slit lamp is a diagnostic tool and cannot perform surgical procedures like laser iridectomy. Such procedures require specific laser devices designed for therapeutic interventions.

Question 14 (Locked)

Q-14: Gold standard for measurement of IOP is:

A Digital tonometry

B Schiotz tonometry

C Pneumotonometry

D Applanation tonometry

Answer: D) Applanation tonometry

Goldmann Applanation Tonometry is widely regarded as the gold standard for measuring intraocular pressure. It works by measuring the force required to flatten a fixed area of the cornea and is considered the most accurate method for glaucoma diagnosis and management.

Question 15 (Locked)

Q-15: Which laser is used in the management of after-cataract?

A Argon

B Krypton

C Nd:YAG

D Excimer

Answer: C) Nd:YAG

The Nd:YAG laser is the standard tool used for posterior capsulotomy to disrupt opacified posterior capsule. This restores clear vision in patients who develop after-cataract following cataract surgery.

Question 16 (Locked)

Q-16: Instrument used to measure phoria for near (33 cm) is:

A Maddox rod

B Maddox wing

C RAF rule

D None of the above

Answer: B) Maddox wing

The Maddox wing is specifically designed for measuring heterophoria at near distance (typically 33 cm). It uses a combination of red and white lights with a dissociating effect to quantify the deviation.

Question 17 (Locked)

Q-17: Auto-refractometer is a method of refraction:

A Subjective

B Objective

C Both of the above

D None of the above

Answer: B) Objective

Auto-refractometry is an objective method of refraction that measures the eye’s refractive error without requiring patient responses. It provides a reliable starting point for subjective refraction.

Question 18 (Locked)

Q-18: Jackson’s cross cylinder is used to check:

A Axis of the cylinder

B Power of the cylinder

C Both of the above

D None of the above

Answer: C) Both of the above

The Jackson Cross Cylinder is used to refine both the axis and power of the cylindrical correction during subjective refraction. It allows precise adjustment of astigmatic correction by presenting two alternative lens positions.

Question 19 (Locked)

Q-19: Keratometry measures:

A Retinal thickness

B Corneal curvature

C Lens power

D Visual fields

Answer: B) Corneal curvature

Keratometry measures the radius of curvature of the anterior corneal surface. This measurement is essential for contact lens fitting, IOL power calculation, and diagnosing corneal conditions like keratoconus.

Question 20 (Locked)

Q-20: Which instrument is used to measure intraocular pressure?

A Perimeter

B Retinoscope

C Tonometer

D Ophthalmoscope

Answer: C) Tonometer

A tonometer is the instrument used to measure intraocular pressure, with Goldmann Applanation Tonometry being the gold standard. Regular IOP measurement is essential for glaucoma diagnosis and management.

🎯 Accelerate Your Optometry Exam Prep

Access high-yield study resources, smart mock tests, and a high-performance community.

🎯 Enroll in Full Govt Job Preparation Course

.

JKSSB Ophthalmic Technician PYQs

.

Gov Job Preparation Course Promotion
EXCLUSIVE APP COURSE

Master Your Gov Job Prep

Join our comprehensive “Gov Job Preparation” course available exclusively on the Optometry Notes & MCQs App.

The Ultimate Success Strategy

Follow this proven sequence to maximize your preparation and secure your goal.

1
📚

Subjects wise Theory Notes

Build a strong foundation by mastering the core theoretical concepts for each subject.

2
🎬

Premium Lectures & Videos

Deepen your understanding with expert video explanations and fundamental optometry lectures.

3

Subjects wise MCQs

Test your knowledge and practice applying concepts with targeted multiple-choice questions.

🏆
🕰️

Previous Year MCQs

Familiarize yourself with actual exam patterns and gauge your readiness with past papers.

Ready to Start Your Journey?

.

About the JKSSB Junior Ophthalmic Technician Recruitment

The JKSSB Junior Ophthalmic Technician recruitment conducted by the Jammu & Kashmir Services Selection Board is one of the most sought-after opportunities for eye care professionals seeking government positions under the Health and Medical Education Department. Released periodically to fulfill technical healthcare requirements across various district and divisional cadres, this JKSSB optometry vacancy offers a Level-4 pay scale position dedicated to primary clinical assistance, vision screening, and ophthalmic diagnostic support.

Securing a post through the JKSSB Ophthalmic Technician Recruitment requires thorough preparation across specialized ophthalmic subjects as well as general medical sciences. Because selection is determined purely on merit scored in the written objective examination, mastering subject-wise Multiple Choice Questions (MCQs) and understanding the official exam pattern are essential steps toward qualifying.

Key Highlights of the JKSSB Optometry Vacancy

  • Recruiting Body: Jammu & Kashmir Services Selection Board (JKSSB)
  • Department: Health and Medical Education Department
  • Post Title: Junior Ophthalmic Technician / Ophthalmic Assistant
  • Pay Scale: Level-4
  • Cadres: Divisional and District Cadres (UT of Jammu & Kashmir)
  • Selection Mode: Objective Type Written Examination (OMR / Computer-Based Test)
  • Language Medium: English Only

Prescribed Educational Qualification & Eligibility

To apply under the JKSSB Junior Ophthalmic Technician recruitment, candidates must satisfy specific educational benchmarks set by the recruitment board:

  1. Basic Qualification: Matriculation (10th standard) or above from a recognized board.
  2. Technical Qualification: A recognized Degree or Diploma in Ophthalmic Technician Course / Ophthalmic Techniques from a state- or central-recognized medical institute or paramedical council.
  3. Equivalence for Optometry Graduates: Candidates holding higher qualifications such as a Bachelor of Science (B.Sc.) in Optometry or a Diploma in Optometry must ensure their qualification is backed by an official Equivalence Certificate from the competent authority/university if required during document verification.
  4. Domicile Criteria: Applicants must hold a valid Domicile Certificate of the Union Territory of Jammu & Kashmir.

Examination Pattern & Marking Scheme

The selection process for the JKSSB Ophthalmic Technician Recruitment involves a competitive written test structured as follows:

  • Question Format: Multiple Choice Questions (MCQs) covering foundational and advanced ophthalmic concepts.
  • Negative Marking: There is a penalty of 0.25 (one-fourth) marks for every incorrect answer.
  • Core Technical Focus: The majority of the syllabus is dedicated to domain-specific subjects, including Ocular Anatomy, Ocular Physiology, Optics, Refraction, Ophthalmic Instrumentation, Ocular Pathology, Pharmacology, and Community Ophthalmology.
  • Merit-Based Allocation: Final appointment lists are drafted strictly on the basis of written test scores combined with candidate cadre preferences and successful document verification.

Why Subject-Wise MCQ Practice is Crucial for Selection

Success in the JKSSB Junior Ophthalmic Technician recruitment examination depends on high accuracy and rapid recall under time pressure. Reviewing past questions by individual subject helps candidates:

  • Pinpoint high-yield topics frequently targeted by the JKSSB exam panel.
  • Master difficult optical formulas, anatomical landmarks, and pharmacological contraindications.
  • Minimize negative marking by testing diagnostic reasoning before the actual test.
  • Bridge the conceptual gap between theoretical optometry textbooks and clinical technician-level applications.

Use the curated previous year questions and topic-wise mock tests provided in this series to build subject mastery and secure your seat in the JKSSB optometry vacancy.

👉 View Full Course Overview & Success Stories

📲 Download the Optometry Notes & MCQs App on Google Play Store

Leave a Reply

Your email address will not be published. Required fields are marked *

Study Optometry Smartly with Smart Optometry Academy

Features

Most Recent Posts

  • All Post
  • Abroad Entrance
  • Binocular Vision
  • Blog
  • Clinical Refraction
  • Contact Lens
  • Courses Overview
  • Dispensing Optics
  • Dubai Health Authority (DHA)
  • HAAD
  • Instrumentation
  • MCQs Tests
  • Ocular Diseases
  • Optometry Tests
    •   Back
    • AIIMS Optometry Exam
    • RRB Optometry Exam
    • PSC Optometry Exam
    • MP Ophthalmic Assistant
    • Gujarat (GSSSB) Ophthalmic Assistant
    • BFUHS Ophthalmic Officer
    • DSSSB Optometry Vacacy
    • General Knowledge MCQs
    • ALIMCO Optometry Vacancy
    • JKSSB- Ophthalmic Technician
    •   Back
    • Optometry Gov Job
    • Current Affairs MCQs
    • AIIMS Optometry Exam
    • RRB Optometry Exam
    • PSC Optometry Exam
    • MP Ophthalmic Assistant
    • Gujarat (GSSSB) Ophthalmic Assistant
    • BFUHS Ophthalmic Officer
    • DSSSB Optometry Vacacy
    • General Knowledge MCQs
    • ALIMCO Optometry Vacancy
    • JKSSB- Ophthalmic Technician
    •   Back
    • MOH Optometry
    •   Back
    • Ophthalmic Officer Exam
    •   Back
    • Retinoscopy/Refraction

Optometry Notes & MCQs

Get well organized notes for all Optometry Subjects

Category

Smart Optometry Academy

Study Optometry Smartly with Smart Optometry Academy

© 2024 Samir Sutradhar